Compare Temblor Subwoofer Models

The Temblor™ T8 and T10 are similar in many respects. The T10 is designed primarily for studio use. While also suitable for the studio, the T8’s input/output configuration and general design make it a particularly good choice for use with small monitors such as the PreSonus® Ceres™ BT-series and Eris E4.5 full-range speakers and in home stereo and home theater systems.


Temblor T8


Temblor T10

MAIN COMPONENTS
Transducer8”, downward firing10”, front-firing
Acoustic PortRear-firing bass reflex (round)Front-firing bass reflex
FEATURES
Input Gain ControlYesYes
Variable Lowpass FilterYesYes
Built-In CrossoverYesYes
Switchable Highpass FilterYesYes
Momentary Footswitch (Bypass)NoYes
Polarity InvertYesYes
Ground-Lift SwitchNoYes
Class AB Amplification200W250W
INPUTS AND OUTPUTS
Main Inputs
  • 2- Balanced ¼” TRS
  • 2- Unbalanced RCA
  • 2- Balanced XLR
  • 2- Balanced ¼” TRS
  • 2- Unbalanced RCA
Main Outputs
  • 2- Balanced ¼” TRS (full range with 80 Hz HPF option)
    2- Unbalanced RCA (full range with 80 Hz HPF option)
  • 2- Balanced XLR (full range with 80 Hz HPF option)
    2- Balanced ¼” TRS (full range with 80 Hz HPF option)
Subwoofer Output (connect a second subwoofer)1- Balanced XLR
PHYSICAL

Width

10.2” (260 mm)12.6” (320 mm)

Depth

12.6” (320 mm)15.75” (400 mm)

Height

11” (280 mm)15.75” (400 mm)

Weight

21.2 lbs (9.6 kg)39.46 lbs (17.9 kg)





Main components

  • T8: 8-inch, downward-firing, glass-composite low-frequency transducer
  • T8: Round, rear-firing, bass-reflex acoustic port
  • T10: 10-inch, front-firing, glass-composite low-frequency transducer
  • T10: Front-firing, bass-reflex acoustic port


​Controls and filters

  • Input gain control (-30 dB to +6 dB, continuously variable)
  • Continuously variable lowpass filter (50 Hz to 130 Hz)
  • Built-in crossover
  • Switchable highpass filter removes frequency content below 80 Hz from the full-range signal sent from the Temblor outputs to the main monitors
  • T10: Momentary footswitch (included) bypasses the subwoofer, highpass filter, and Sub Out
  • Polarity invert
  • T10: Ground-lift switch


Power and safety

  • T8: 200 watt, Class AB amplification
  • T10: 250 watt, Class AB amplification
  • Internal damping and heat sink
  • Integrated rubber feet for stable placement


Inputs and outputs

  • T8: Left and right, balanced ¼” TRS and unbalanced RCA main inputs
  • T10: Left and right, balanced XLR and ¼” TRS and unbalanced RCA main inputs
  • T8: Left and right, balanced ¼” TRS and unbalanced RCA outputs
  • T10: Left and right balanced XLR and ¼” TRS outputs 
  • T10: XLR subwoofer output for connecting a second T10







Temblor® T8

Temblor® T10

Inputs

  • 2- Balanced ¼” TRS
  • 2- Unbalanced RCA
  • 2- Balanced XLR
  • 2- Balanced ¼” TRS
  • 2- Unbalanced RCA

Outputs

  • 2- Balanced ¼” TRS (full range with 80 Hz HPF option
  • 2- Unbalanced RCA (full range with 80 Hz HPF option)
  • 2- Balanced XLR (full range with 80 Hz HPF option)
  • 2- Balanced ¼” TRS (full range with 80 Hz HPF option)
  • 1- Balanced XLR (Sub Out)

Performance

Frequency Response30 Hz – 200 Hz20 Hz – 200 HzLow Pass Filter Frequency50 – 130 Hz (variable)50 – 130 Hz (variable)Signal-to-Noise Ratio>98 dB (A weighted)>98 dB (A weighted)THD0.05%0.019% @ power <160WAmplifier Power200W peak, 100W RMS250W peak, 170W RMSPower Consumption120W230WAmplifier TypeClass ABClass ABPeak SPL at 1m104 dB113 dBWoofer8” glass-composite, downward-firing10” glass-composite, front-firingAcoustic PortRear-firing bass reflex (round)Front-firing bass reflex

User Controls

Input Gain Range-30 to +6 dB-30 to +6 dBPolarity Switch0° or 180°0° or 180°Low Pass Filter Control50 Hz to 130 Hz50 Hz to 130 HzGround Lift Switch

On/OffHigh Pass Filter SwitchOn/OffOn/OffBypass Footswitch

On/Off

Protection

  • RF interference
  • Output-current limiting
  • Over-temperature
  • Turn-on/off transient
  • Subsonic filter
  • External mains fuse
  • RF interference
  • Output-current limiting
  • Over-temperature
  • Turn-on/off transient
  • Subsonic filter
  • External mains fuse

Power

100-120V ~50/60 Hz or 220-240V ~50/60 Hz100-120V ~50/60 Hz or 220-240V ~50/60 Hz

Cabinet

Vinyl-laminated MDFVinyl-laminated MDF

Physical

Width10.2” (260 mm)12.6” (320 mm)Depth12.6” (320 mm)15.75” (400 mm)Height11” (280 mm)15.75” (400 mm)Weight21.2 lbs (9.6 kg)39.46 lbs (17.9 kg)




T8               T10